

Unexpected happened' type of message, with as much diagnostic detail as Any unidentified case should trigger an 'oops, something It should only be shown if its own special case has been actively There are a number of specialĬase alerts, but if no special case is identified, this message is the Seconds an error message appears telling you the password is wrong.Īnd it's extremely bad programming practice. Restart BOINC Manager, it will try to connect to localhost but after a few I eventually resorted to boinccmd -quit, which worked. read_cc_config, but this reported retval 0 and made no change to theĬlient behaviour.
#Seti boinc password reset manual#
I tried to restore normality with a manual edit to cc_config.xml and boinccmd Started to re-display about every second - too quick to make sense of the Name), the Event log showed RPC messages flowing. The task pane started to display one task (without the project Negating point 4 above) but failed to populate the manager screensĬompletely. On restarting the Manager, the client reconnected immediately (thus On Mon, at 11:33 AM RichardHaselgrove wrote: Any unidentified case should trigger an 'oops, something unexpected happened' type of message, with as much diagnostic detail as possible. It should only be shown if its own special case has been actively identified. There are a number of special case alerts, but if no special case is identified, this message is the final else. This message comes from, and it's extremely bad programming practice. Restart BOINC Manager, it will try to connect to localhost but after a few seconds an error message appears telling you the password is wrong. I tried to restore normality with a manual edit to cc_config.xml and boinccmd -read_cc_config, but this reported retval 0 and made no change to the client behaviour. Both panes cleared and started to re-display about every second - too quick to make sense of the contents. The task pane started to display one task (without the project name), the Event log showed RPC messages flowing. On restarting the Manager, the client reconnected immediately (thus negating point 4 above) but failed to populate the manager screens completely. I (deliberately) left the client running and quit the Manager.

I'll try to check every now and then to not keep you waiting too long. If any other information from my side is required, just ask for it.

running projects: Citizen Science Grid,, nanohub_at_home, and As far as I can see, all the other flags are working fine (for now).Not sure if this is relevant, but since it is BOINC related, I'll give the info anyway: Normal connection with localhost and BOINC tasks starting on BOINC Manager startup, even when this log flag is enabled.
#Seti boinc password reset install#
Manual fix (not permanent, will crash again if above steps are repeated): go to the BOINC install folder and in cc_config.xml, edit the line 1 to 0, then save and BOINC will be fine again after another restart.Restart BOINC Manager, it will try to connect to localhost but after a few seconds an error message appears telling you the password is wrong.Close BOINC Manager completely, click OK on the shutdown pop-up if necessary (with 'stop active tasks.Make sure gui_rpc_debug is checked and hit Save or Apply.In the Advanced view, choose Options>Log options.In the Advanced view of the BOINC Manager, activation of the log flag gui_rpc_debug causes trouble at the next restart of BOINC Manager.
